Laser Rangefinder Module 0105C
TECHNICAL SPECIFICATIONS
- Function
The main functions of DYC-20B small laser range finder are:
a) Laser ranging function;
b) Power on and temperature collection function;
c) With distance gating function;
d) Equipped with first/last target ranging function;
e) Equipped with laser self-check and self-check query functions;
f)Equipped with serial port update program function.
- Performance
The main performance indicators are as follows:
a) Working wavelength: 1535nm±5nm;
b) Ranging capability: ≥1200m (visibility ≥5Km, target reflection coefficient 0.3, relative humidity ≤60%, for 1.7m×0.5m standard target plate or equivalent target);
c) Ranging blind zone: ≤30m;
d) Distance measurement accuracy: ≤±1m;
e) Ranging frequency: single, 1Hz, 5Hz, 10Hz;
f) Accuracy rate: ≥98%;
g) False alarm rate: ≤1%;
h) Divergence angle: ≤1mrad;
i) Distance resolution: ≤48m.
- Applicable environmental conditions
a) Working temperature: -40℃~+60℃;
b) Storage temperature: -55℃~+70℃;
c)Vibration: Place the sample machine in the storage box, and conduct a vibration test in three mutually perpendicular axes (one of which is parallel to the optical axis of the objective lens) according to Figure C.3 and Table C.7 in GJB 150.16A-2009. , vibrate for 40 minutes in each direction. After the vibration is completed, all functions of the laser rangefinder are normal and can still work normally.
- Security
In order to ensure the safety of test subjects and test personnel, the following safety measures were taken during the design process of the LRF0105C small laser range finder:
a) Conduct safety design and analysis in accordance with GJB 900A-2012 "General Requirements for Equipment Safety Work";
b) Use non-flammable materials, and the mechanical and electrical interface connections are stable and reliable;
c) The components that control key systems and key functions have error-proof designs;
d) Take reasonable design measures to avoid water vapor accumulation and cause short circuit;
e) Use eye-safe laser as the working band;
f) Work below the human body safety voltage.