Laser Ranging Target Designator 100mJ
TECHNICAL SPECIFICATIONS
Wavelength |
1064nm |
Output Energy |
Full temperature range: 100mJ~120mJ, Average output energy ≥110mJ |
Adjacent pulse energy fluctuation range |
≤8% |
Beam Divergence Angle |
≤0.15mrad (Accepted by the sleeve hole method, the ratio of hole to no-hole is not less than 86.5%) |
Beam Pointing Stability |
≤0.03mrad (1σ) |
Irradiation Frequency |
Precisely coded from 45ms to 56ms (checksum 20Hz) |
Pulse Period Accuracy |
≤±2.5μs |
Pulse Width |
15ns±5ns |
Irradiation Time |
Not less than 90s, interval 60s, or not less than 60s, interval 30s, continuous irradiation for 4 cycles at room temperature and low temperature, and 2 cycles at high temperature |
Ranging Range |
Minimum value not greater than 300m, maximum value not less than 35km (23km visibility, medium atmospheric turbulence, for a 2.3m×2.3m target with a target reflection coefficient greater than 0.2) |
Irradiation Distance |
Not less than 16km for a 2.3m×2.3m target |
Preparation time for powering on at room temperature |
< 30 seconds |
Preparation time for low-temperature power-on |
< 3 minutes |
Service Life |
≥2 million times |
Ranging Count Range |
200m~40km |
Ranging Accuracy |
±2m |
Accuracy Rate |
≥98% |
Ranging Frequency |
1Hz, 5Hz, 10Hz, 20Hz |
Installation Reference Plane Non-Parallelism with Laser Emission Optics Axis |
≤0.5mrad |
Installation Reference Plane Flatness |
0.01mm(Design guarantee) |
Dimensions |
239mm ╳ 116mm ╳ 81mm |
Weight |
2500g |