1535nm Eyesafe Laser Rangefinder Module 1221C
SPECIFICATIONS
Parameters |
Unit |
Argument |
Comments |
Safety Class |
- |
Class 1 |
Eyesafe |
Wavelength |
nm |
1535±5 |
- |
Ranging Capability |
m |
≥5000 |
Target of 0.5m ×1.7m visibility of 5km |
≥12000 |
Target of 2.3m × 2.3m visibility of 15km |
||
≥21000 |
Target of 4m × 6m of 25km |
||
Min Measuring Range |
m |
≤50 |
|
Range Accuracy |
m |
≤±2 |
Affected by weather conditions and target reflectivity |
Measuring Rate |
Hz |
0.5~10 |
- |
Multiple Targets |
- |
5 |
- |
Precision |
% |
≥98 |
- |
False Alarm Rate |
% |
≤1 |
Probability of occurrence of noise |
Dimensions |
mm |
134×60×58 |
L×W×H |
Weight |
g |
≤320 |
- |
Data Interface |
- |
molex-532610771 |
Other interfaces can be customized |
Power Supply |
v |
12 |
- |
Peak Power Consumption |
w |
3 |
Max power consumption when start up |
Standby Power Consumption |
w |
1.5 |
Function to be shut down by external signal can be customized |
Vibration |
- |
5Hz, 2.5g |
- |
Shock |
- |
Axial 100g, 1ms |
Can be increased based on user’s application scenarios |
Operation Temperature |
℃ |
-40~+65 |
- |
Storage Temperature |
℃ |
-55~+70 |
- |